Cavitation is the fastest way to destroy a pump impeller - and it is almost always a suction-side problem, not a pump quality problem. Understanding NPSH (Net Positive Suction Head) is the key to avoiding it.
1. What happens during cavitation
If the pressure at the pump suction drops below the vapour pressure of the liquid, the liquid flashes into tiny vapour bubbles. When these bubbles reach the higher-pressure area of the impeller, they collapse violently, blasting the metal surface. Repeated collapse erodes the impeller, causes noise ("gravel in the pump" sound), vibration, and a drop in performance.
2. The two numbers: NPSH available vs NPSH required
| Term | Meaning | Who controls it |
|---|---|---|
| NPSH available (NPSHa) | The suction energy your system actually provides to the pump at the impeller eye. It comes from atmospheric/static pressure on the liquid surface, minus suction lift, friction losses and vapour pressure. | You - it depends on tank level, pipe size, layout and liquid temperature. |
| NPSH required (NPSHr) | The minimum suction energy the pump needs to run without cavitation at a given flow. It is printed on the pump curve. | The pump manufacturer. |
3. Quick way to check your suction side
- Keep the pump as low and close to the liquid source as possible (positive suction head beats suction lift);
- Use short, straight, adequately sized suction pipework - avoid long horizontal runs, tight bends and strainers that add friction;
- Watch liquid temperature - hot liquids vapourise more easily and need extra NPSH margin;
- Never throttle the suction valve; throttling the discharge moves the pump into a worse NPSH condition.
4. Example: XA pump at 50 m³/h
If the XA curve lists NPSHr ≈ 3.2 m at the duty point and your tank level gives NPSHa ≈ 5.5 m, you have ≈2.3 m of margin - a safe design. If a blocked strainer drops NPSHa to 3.0 m, cavitation begins. The fix is usually on the piping side, not the pump.