1. Judging by the analysis of the wear of the parts when the pump is disassembled:
A. The port ring of the pump body and the port ring of the impeller are worn, indicating that the inner diameter of the bearing is excessively worn, and the bearing needs to be replaced.
B. The front cover plate of the impeller and the pump body are worn, indicating that the end face of the front bearing is excessively worn, and the bearing needs to be replaced.
C. The inner diameter of the bearing is worn, the shaft sleeve and the thrust plate are worn and the color turns black, indicating that the gas in the motor cavity is not drained, lacking liquid or idling, and spare parts need to be replaced.
D. The end face of the front bearing and the surface of the thrust plate are worn, and the rear bearing and the thrust plate are not worn, indicating that the shaft thrust is forward and the pump is in a state of lack of liquid. Check for clogged inlet filters, insufficient fluid supply to the system, and pump cavitation.
E. The end face of the rear bearing and the surface of the thrust plate are worn, and the front bearing and the thrust plate are not worn, indicating that the shaft thrust is backward, and the flow may be too large. Check whether the outlet valve is opened too much.
F. The stator and rotor shielding sleeves are worn, and the inner diameter of the bearing does not exceed the limit value, indicating that foreign matter has entered the motor cavity. Check whether the inlet filter is damaged.
2. Judging by the vibration and noise analysis of the pump:
A. The pump vibrates, and the vibration source comes from the two bearings of the motor part, indicating that the bearings are worn, and the bearing wear needs to be checked.
B. The pump vibrates, the source of vibration comes from the pump body, the pump pressure is normal when the outlet valve is closed, but the pressure gauge indicates a sudden drop when the valve is opened, and the operating current is lower than the normal value, indicating that the pump is in cavitation state, and the inlet liquid level needs to be increased High satisfaction: device NPSH = 1.3 × pump NPSH.
C. The pump is vibrating, there is noise, the TRG meter indicates in the red area, and the pressure gauge at the pump outlet is not too large for normal pressure, indicating that the pump is reversed, and the phase sequence of the power line needs to be adjusted.
3. Analysis and judgment indicated by the TRG table:
A. The table indicates in the yellow zone or the red zone (other conditions are normal), indicating that the bearing is worn and needs to be replaced.
B. The meter indicates in the green area, but the bearing on the motor side vibrates. After the disassembly, the bearing has been excessively worn, indicating that the module is faulty and cannot be replaced normally.
C. After the pump is turned on for the first time or the power line is reconnected (that is, when the bearing is not worn), the meter indicates in the red area, indicating that the pump is in reverse rotation, and the phase sequence of the power line needs to be adjusted.
D. After the pump is turned on, the meter has no response, and the motor has a small humming sound, indicating that the pump power line is out of phase, and the electrical circuit needs to be checked.
E. After the pump is turned on, the meter has no response, but the outlet pressure and current are all normal, indicating that the meter is damaged and needs to be replaced with a new meter.
F. After driving, the indicator of the meter is too large and not at the zero position (in the case of confirming that the bearing is not worn). After disconnecting the three wires U, V and W on the module from the terminal, then turn on the pump and indicate that the pointer is at the zero position, indicating that the voltage is too high , There is a magnetic field or frequency conversion equipment that interferes with the meter, which can be solved by replacing the frequency conversion module.